Text Us
    Back to Home

    Hot Water Recirculation Pumps in Greer, SC

    Run the shower for a minute before it gets warm? A hot water recirculation pump keeps hot water near your fixtures so it arrives in seconds. We install new pumps, and fix systems that aren't delivering hot water any faster.

    Hot Water Recirculation Pumps

    Straight From The Field

    Recent Hot Water Recirculation Pumps Jobs

    Real hot water recirculation pumps work we've completed across the Upstate.

    Hot Water Recirculation Pump Installed Near Tigerville Road in Travelers Rest, S, Off Tigerville Road, Travelers Rest (photo 1 of 2)

    Off Tigerville Road, Travelers Rest

    Hot Water Recirculation Pump Installed Near Tigerville Road in Travelers Rest, SC 🔧💧 Another customer in the Travelers Rest area near Tigerville Road was dealing with long wait times for hot water and inconsistent…

    See more
    CallFrom Google
    Troubleshooting a Navien tankless water heater recirculating pump today in Simps, Simpsonville, SC

    Simpsonville, SC

    Troubleshooting a Navien tankless water heater recirculating pump today in Simpsonville, South Carolina. The homeowner was experiencing long wait times for hot water and inconsistent performance throughout the house…

    See more
    CallFrom Google

    About This Service

    The wait happens because the hot water sitting in the pipes has cooled off, and it has to run down the drain before hot water from the heater reaches you. The farther a fixture is from the water heater, the longer the wait. A recirculation pump moves that water back toward the heater so the line stays warm.

    There are two ways to set it up. Homes plumbed with a dedicated return line get a pump on that return, and hot water circulates in a loop. Many existing homes don't have a return line, so a retrofit system puts a small valve under the sink farthest from the water heater, connecting the hot and cold lines there, and a pump on the hot side at the heater sends water around through the cold line. Because of that, the cold tap at that sink can run warm for a moment. Tankless heaters add a wrinkle: Navien builds recirculation into its ComfortFlow models, with a small buffer tank, and a tankless heater only fires above a minimum flow (0.5 gallons a minute on Navien's NPE-A2), so an add-on pump has to be set up to the heater's manual.

    How it's controlled matters as much as the pump. ENERGY STAR notes that systems running continuously can use more energy than they save, and lists the demand controls: a button, a timer or a motion sensor. The Department of Energy calls demand-initiated control the best way to run the pump.

    We've done both sides of this work. Near Tigerville Road in Travelers Rest, a family waited a long time for hot water and got uneven temperatures through the house, and we installed a recirculation pump. In Simpsonville, a homeowner with a Navien tankless and a recirculating pump was still waiting on hot water; we checked the recirculation settings, the pump, the check valves and the line setup, and left the system running to the manufacturer's standards.

    Signs You May Need Hot Water Recirculation Pumps

    • Running a faucet or shower for a minute or more before it gets hot
    • Hot water that comes and goes during a shower
    • A recirculation pump that runs but hot water isn't any faster
    • A cold tap that runs warm after a recirculation valve was installed
    • A tankless water heater with recirculation that isn't working right
    • A pump that's noisy or has stopped running

    What's Included

    • Hot water recirculation pump installation
    • Water heater recirculation pump replacement
    • Tankless recirculation pump replacement
    • Navien NPE-210 and NPE-240 recirculation installation
    • Navien and tankless recirculation troubleshooting
    • Check valve and line configuration checks

    Why Choose Us

    • We check the settings, valves and lines before replacing the pump
    • We work on tankless recirculation, not just tank systems
    • Licensed in South Carolina and North Carolina
    • Veteran-owned local plumber in Greer

    Hot Water Recirculation Pumps FAQ

    It depends on the system. With a dedicated return line, the pump sits on the return. In a retrofit system without a return line, the pump is on the hot side at the water heater and the cold line carries water back, through a valve under the farthest sink.

    No, but some have one built in, like Navien's ComfortFlow models, which add a small buffer tank. A tankless heater only fires above a minimum flow, so an add-on pump has to be set up to the heater's manual.

    Listen for it running when it should be, and check its timer or settings. If it runs and hot water still takes as long, look at the check valves and the valve under the sink, which are what we check first.

    Running it all the time can. Navien notes energy use goes up when recirculation is on, and ENERGY STAR says continuous systems use more. Running it on demand or on a timer keeps the extra use down.

    In a retrofit system, hot water circulates back through the cold line, so the cold tap at that sink can run warm briefly. If it stays warm or happens at other fixtures, a valve or check valve may be stuck. Call 864-279-4461.