Bradford White Water Heaters in Greer, SC
We install Bradford White tank water heaters. Bradford White sells only through professionals, so you won't find one at a big box store. We install them gas and electric, 40 and 50 gallon, including lowboys for tight crawl spaces. Here's how to tell how old yours is, light the pilot, and read the status light, from Bradford White's own documents.

About This Service
Our Bradford White installs run across the Upstate. On Croft Street in Greenville, an emergency call replaced a failing 40-gallon gas heater with a new 40-gallon Bradford White gas unit. On Pinegate Drive in Greenville, water around the base turned out to be a hole in the bottom of the tank, and a new 50-gallon Bradford White went in the same day. Near West Blackstock Road in Spartanburg we installed a 40-gallon Bradford White gas heater. In Travelers Rest an old 40-gallon came out and a 50-gallon Bradford White went in, and a main shutoff that wasn't working properly got a new full-port ball valve. And in a Greer crawl space too tight for a standard tank, we installed a 50-gallon Bradford White lowboy electric with new PEX lines, a shutoff valve, an expansion tank, an updated T&P valve and a proper drain pan setup.
To tell how old a Bradford White is, look at the first two characters of the serial number on the rating plate: the first is the year and the second is the month. Bradford White's chart runs A for 2004 or 2024 through Z for 2023 or 2043 (it skips I, O, Q, R, U and V), so each letter means two possible years 20 years apart, and the month letters run A for January through M for December, skipping I. A serial starting with "TA" is January 2019. You can also enter the serial number on Bradford White's My Water Heater page to see the manufacture date. Bradford White says its water heaters can last 10 years or more with a professional installation and proper maintenance, and that harsh water and natural gas quality can shorten that.
On models with Bradford White's ICON gas control, the pilot is lit by a piezo igniter, not a match, and Bradford White's label says not to open the inner door to light it by hand. The steps on the label: set the gas control knob to OFF, wait five minutes to clear out any gas, then smell for gas, including near the floor; if you smell gas, stop. Then turn the knob to PILOT, hold it in, press the igniter button until it clicks, and keep holding until the status light blinks (on its mechanical White Rodgers control, the label says to hold the knob about one minute after the pilot lights). If the pilot won't stay lit after several tries, Bradford White says to turn the knob to OFF and call your technician or gas supplier. Its FAQ adds that under normal operation the pilot should only have to be lit once, at installation, so repeated pilot outages are a reason to call a plumber.
The status light on the ICON gas valve is a troubleshooting tool. On ICON 2.0 controls (atmospheric and direct-vent models with serial date code "TA", January 2019, or later; if your serial is at or near TA, Bradford White says to verify the control generation with its Technical Support), one flash with a four-second pause means the knob is in the pilot position or the thermostat is satisfied, one flash every second means it's calling for heat, two flashes mean a weak pilot signal, four flashes mean high tank temperature, and five flashes mean a thermostat sensor fault. A solid light isn't an error: the control is shutting down, and Bradford White says to wait until the light goes out before relighting. Its FAQ says the lights are designed to help the professional plumber, and to contact one if the heater isn't working.
Bradford White's reset procedures are in its service manuals, which are for qualified service providers. Its homeowner manuals say that if the heater overheats or the gas doesn't shut off, turn off the gas or electric supply and call a qualified technician. Its Defender Safety System shuts the burner down if flammable vapors are drawn in and ignite; after a flammable vapor shutdown, Bradford White says to replace the water heater, and that replacement isn't covered by the warranty.
When a Bradford White runs out of hot water too fast, its service manual's chart for White Rodgers mechanical gas controls starts with the thermostat set too low, very cold incoming water, high demand and a heater too small for the house, then a control out of calibration and an out-of-spec dip tube mixing cold water into the hot. Its electric service manual says the most common cause of improper operation is heating element failure.
The warranty is in the model number. Bradford White's residential tank warranty runs 1, 6, 8 or 10 years on the tank in a single-family home, depending on the model (an RG240T6N has a 6-year tank warranty), with parts covered for 6 years, both from the date of installation. Labor and installation aren't covered, and it doesn't cover leakage or malfunction caused by installing the heater in a closed system without provisions to manage thermal expansion. Most homes here are closed systems; see our expansion tank page. Bradford White says its 6-year and 10-year products are of identical quality.
Signs You May Need Bradford White Water Heaters
- Water around the base of the tank
- A pilot that won't stay lit
- A blinking status light on the gas valve
- Hot water that runs out fast
- A heater over 10 years old by its date code
- A crawl space or closet too short for a standard tank
What's Included
- Bradford White gas water heater installation, 40 and 50 gallon
- Bradford White electric and lowboy installation
- Expansion tank, T&P valve and drain pan with the install
- Shutoff valve and supply line replacement
- Pilot, thermocouple and gas valve repair
- Heating element and thermostat repair
- Bradford White gas tankless installation
Why Choose Us
- Sold through professionals, installed by one
- Same-day replacement available
- Licensed in South Carolina and North Carolina
- Veteran-owned local plumber in Greer
Bradford White Water Heaters FAQ
Bradford White Water Heaters Near You
We provide bradford white water heaters to homeowners and businesses across the Upstate SC area. Select your city to see local service info.
Sources
- Bradford White: My Water Heater (serial number date code)
- Bradford White: FAQs
- Bradford White: residential gas installation & operating manual (lighting, Defender)
- Bradford White: gas quick service guide (ICON status light codes)
- Bradford White: residential gas service manual
- Bradford White: residential electric service manual
- Bradford White: residential tank limited warranty
- Bradford White: electric lowboy specification sheet
- Bradford White: Infiniti GS tankless specification sheet
- Bradford White: tankless water heaters