    A backflow preventer keeps water that has left the public system from flowing back into it. What your house needs depends on your water utility and on what's connected: an irrigation system, a well, fire sprinklers. Frontline Plumbing replaces residential backflow preventers and hose bibb vacuum breakers in Greer and across the Upstate.

    Backflow Preventers

    About This Service

    Greenville Water defines backflow as "the reversal of flow in a water distribution system as a result of back pressure or back siphonage." The utilities' manuals define the devices you'll find on a house. A residential dual check is two spring-assisted check valves with no shutoff valves or test cocks. A double check valve assembly (DCVA) adds test cocks and a shutoff valve at each end. Spartanburg Water's manual approves a pressure vacuum breaker (PVB) only for back-siphonage and requires it 12 inches above any downstream piping or outlets, or flood level rim. A reduced pressure (RP) assembly has two check valves with a relief valve between them, for high-hazard connections. South Carolina's residential code also requires a vacuum breaker on hose bibbs and other openings with a hose connection, with exceptions for water heater and boiler drain valves meant only for draining the tank, and washing machine valves where backflow prevention is otherwise provided or built into the machine.

    South Carolina's regulation sets the floor for irrigation: the minimum device for a low-hazard residential lawn sprinkler system is a residential dual check, and an irrigation system with chemical addition, or one also connected to a water source that isn't an approved public water system, is a high-hazard cross connection, which needs an air gap or an RP. Each utility handles homes its own way: - Greenville Water requires a dual check valve on the meter setter for newly installed residential irrigation systems, and Greenville Water replaces its internal parts once every thirty years. Existing irrigation systems with a DCVA are being phased out; if one isn't replaced with a dual check within fifteen years of the policy, it has to be tested then, and every fifteen years after, by a certified tester. - Spartanburg Water installs a residential dual check valve for residential customers with 3/4- to 1-inch meters, and requires at least a dual check on low-hazard lawn irrigation, replaced with its meter change-out program or if it malfunctions. If a house on a private well wants the well to stay connected to its Spartanburg Water service, an RP has to be installed on the customer side of the meter. - Greer CPW's cross-connection control plan (amended April 2025) puts single-family homes in its minimal hazard category, protected by a dual check, says it won't require testing of double checks on low-hazard residential irrigation, and says it changes out the dual check on low-hazard residential irrigation on a ten-year basis. Its customer service manual (effective July 14, 2026) puts it differently: residential accounts with an irrigation system must have a backflow prevention device inspected every ten years, with the inspection charge added to the account.

    Testing is its own trade. South Carolina's regulation says each assembly is tested by a certified tester after installation and at least once a year, and immediately after any repair. The once-a-year rule has one exception: where a utility's written policy designates a testable assembly as the minimum protection for low-hazard residential irrigation, that policy sets the minimum testing frequency. SC DES certifies every backflow tester in the state. Greenville Water says it does not install or test backflow preventers, and certified testers upload results to its portal. The customer pays: Greenville Water's and Greer CPW's manuals make the customer responsible for all costs of purchase, installation, testing and maintenance of required assemblies. If a test is missed, Greenville Water and Spartanburg Water bring in a tester and bill the account, Greer CPW does the same for assemblies at the meter or property line, and all three can suspend or discontinue service.

    Freezing is the other thing that ruins them. The code says backflow preventers can't be located where they'll freeze unless they can be removed by unions or are protected by heat, insulation or both, and the utilities' manuals call for an enclosure. Febco says its assemblies must be drained for the winter where freezing may occur, and that an assembly can't be adequately drained through the test cocks; its steps end with the valves left half open. Watts says to leave the 800M4's test cocks and ball valve handles at a 45° angle.

    Testable assemblies like the Watts 800M4 and Zurn Wilkins 720A are built to be repaired. Watts says the 800M4's internal parts can be removed, repaired or inspected without removing the valve from the piping, and to replace rubber goods every 5 years; Zurn Wilkins says repair kits for its 720A PVB are available from your supplier. The dual checks at the meter are replaced on the utility's schedule. Do a backflow preventer's checks cost you pressure? Some: Watts lists "low pressure drop" for its LF007 double check and publishes flow curves, and Febco describes the 765 PVB as "designed for minimum head loss."

    In Greer we installed an irrigation water meter and tap working directly with Greer CPW, for a homeowner whose irrigation was tied into the house line, and separated the two. We replace residential backflow preventers and hose bibb vacuum breakers. Required tests are done by a state-certified tester.

    Signs You May Need Backflow Preventers

    • A letter from your water utility about a backflow device or test
    • Adding or changing a lawn irrigation system
    • A backflow assembly that leaks or froze
    • An outdoor spigot without a vacuum breaker
    • A well still connected to a house on city water

    What's Included

    • Residential backflow preventer replacement
    • Hose bibb vacuum breaker replacement
    • Separating irrigation from the house water line
    • Irrigation tap and meter work with the utility

    Why Choose Us

    • We work to your utility's manual, not a generic rule
    • Licensed in South Carolina and North Carolina
    • Veteran-owned local plumber in Greer

    Backflow Preventers FAQ

    Most of the utilities here already require one on the service. Greenville Water has required backflow prevention assemblies on all service connections since 1971, Spartanburg Water installs a residential dual check for residential customers with 3/4- to 1-inch meters, and Greer CPW protects single-family homes with a dual check. Irrigation, a connected well or fire sprinklers can require more.

    South Carolina's regulation says each assembly is tested after installation and at least once a year by a certified tester, and right after any repair, except that for low-hazard residential irrigation, where the utility designates a testable assembly, its written policy sets the routine testing frequency. Greenville Water's older residential irrigation double checks are on a fifteen-year rule, and Greer CPW's plan doesn't require testing of double checks on low-hazard residential irrigation, though its 2026 customer service manual says residential irrigation backflow devices are inspected every ten years, with the charge added to the account.

    The customer. Greenville Water's and Greer CPW's manuals make the customer responsible for all costs of purchase, installation, testing and maintenance of required assemblies, and Spartanburg Water says irrigation-meter testing costs are the customer's sole responsibility.

    Watts' instructions for its 007 double check say the product must be installed by a licensed contractor in accordance with local codes. Greenville Water says the customer is responsible for permits and inspections and should contact its cross-connection department before buying or installing one, and a new testable assembly has to be tested by a certified tester before use.

    Febco's winterization sheet for its 765 PVB says to drain it for the winter where freezing may occur, and that draining through the test cocks isn't enough: open the drain valves, then leave the valves half open. Insulation using heat tape and heated protective enclosures are the other methods it lists.

    Some, and manufacturers publish the loss: Watts publishes flow curves and lists "low pressure drop" for its LF007 double check, and Febco describes its 765 PVB as "designed for minimum head loss."